Registration Dossier

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): Ethylene Urea, getrocknet
- Analytical purity: approx. 100 % (The sponsor is responsible for compliance, for all test substance information and their storage.)
- Lot/batch No.: 090/2012 (aus Charge 12-0048)

Results and discussion

For thermal stability study

Test substance thermally stable:
no
Operating temperature
Operating temp.:
30 - 500 °C
Remarks on result:
other: 1st reaction at onset temperature 150 °C, peak temperature 177 °C,energy release 60 J/g; 2nd reaction at onset temperature 395 °C, peak temperature 415 °C, energy release 270 J/g.

Any other information on results incl. tables

Test parameters
Apparatus: Mettler TA 8000
Sample containers: closed high pressure cell made of V4A
Sample weight: 21.3 mg
Reference material: empty container
Heating rate: 2.5 °C/min
Temperature range: from 30 °C to 500 °C
Results
1st reaction:
Onset temperature: 150 °C
Peak temperature: 177 °C
Energy release: 60 J/g
2nd reaction:
Onset temperature: 395 °C
Peak temperature: 415 °C
Energy release: 270 J/g

Sample was handled under nitrogen in glovebox.

Applicant's summary and conclusion