Registration Dossier

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Inhalation: Get medical attention immediately if symptoms occur.
Skin: Wash off immediately with plenty of water. Get medical attention if irritation develops and persists.
Eyes: Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Ingestion: Do NOT induce vomiting.. Call a physician immediately.

Fire-fighting measures

Suitable extinguishing media
Carbon dioxide (CO2), Water spray, Foam, Dry chemical

Special exposure hazards arising from the substance or preparation itself, its combustion products, or released gases
Under conditions giving incomplete combustion, hazardous gases produced may consist of
carbon monoxide
carbon dioxide (CO2)
Combustion gases of organic materials must in principle be graded as inhalation poisons

Special protective equipment for fire-fighters
Wear self-contained breathing apparatus and protective suit.

Accidental release measures

Personal precautions
Avoid contact with the skin and the eyes. Keep away from heat and sources of ignition. Provide adequate ventilation.

Environmental precautions
Prevent further leakage or spillage. Do not discharge into the drains/surface waters/groundwater.

Methods for cleaning up
Use mechanical handling equipment. Dispose of in accordance with local regulations.

Additional information
Consult trained personnel. Consider the information for "Personal Protection" .

Handling and storage

Handling

Hygiene measures
Avoid contact with the skin and the eyes. When using, do not eat, drink or smoke. Wash hands before breaks and at the end of workday.

Advice on safe handling
Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin, eyes and clothing.

Incompatible products
Keep away from:, oxidizing agents

Protection - fire and explosion:
Take measures to prevent the build up of electrostatic charge. Keep away from sources of ignition - No smoking.

Reduce the release of the substance or mixture to the environment
See Section 8: Environmental exposure controls

Temperature class
T4

Storage
Material storage
Keep in a dry, cool place. Protect against light.

Incompatible products
Keep away from:, oxidizing agents

Technical measures/Storage conditions
Keep tightly closed in a dry, cool and well-ventilated place.

German storage class
11: Combustible solids

Transport information

Land transport (ADR/RID)

UN number:
Not regulated
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (ADN(R))

UN number:
Not regulated
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

UN number:
Not regulated
Remarksopen allclose all

Air transport ICAO/IATA

UN number:
Not regulated
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Engineering measures: General or dilution ventilation is frequently insufficient as the sole means of controlling employee exposure. Local ventilation is usually preferred. Explosionproof equipment (for example fans, switches, and grounded ducts) should be used in mechanical ventilation systems.

Personal protective equipment
General advice: Avoid contact with skin and eyes. Do not breathe dust.
Hygiene measures: Avoid contact with the skin and the eyes. When using, do not eat, drink or smoke. Wash hands before breaks and at the end of
work day.
Respiratory protection: respirator with P2 filter. Equipment should conform to EN 136 or EN 140 and EN 143.
Eye protection: Tightly fitting safety goggles Face-shield
Skin protection: protective suit
Hand protection: Chemicals resistant gloves
Suitable material: nitrile rubber
Type: Tricotril (Company KCL) or comparable article; or refer to glove manufacturer's recommendation
Evaluation: according to EN 374: level 6
Material thickness: approx. 1.5 mm
Break through time: 480 min
Suitable material: butyl-rubber
Type: Butoject (Company KCL) or comparable article; or refer to glove manufacturer's recommendation
Evaluation: according to EN 374: level 6
Material thickness: approx. 0.3 mm
Break through time: 480 min

Environmental exposure controls
Do not discharge into the drains/surface waters/groundwater
Environmental Precautions
Should not be released into the environment

Stability and reactivity

Reactivity : Stable under normal conditions of handling, use and transportation.
Chemical Stability : Thermal decomposition can take place above 210°C.
Conditions to avoid : Avoid dust formation.
Incompatible Materials : Keep away from:, oxidizing agents
Hazardous decomposition products : No hazardous decomposition products are known.

Disposal considerations

Product information : Disposal required in compliance with all waste management related state and local regulations. The choice of the appropriate method of disposal depends on the product composition by the time of disposal as well as the local statutes and possibilities for disposal.

Uncleaned empty packaging : Contaminated packaging should be emptied as far as possible and after appropriate cleansing may be taken for reuse.