Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 1992 - January 1993
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Well conducted study according to GLP
Cross-reference
Reason / purpose:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1993
Report Date:
1993

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Batch no 910312

Results and discussion

Vapour pressure
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: First vapour pressure

Applicant's summary and conclusion