Registration Dossier

Administrative data

Endpoint:
sensitisation data (humans)
Type of information:
other: observations in humans
Adequacy of study:
weight of evidence
Study period:
1995-1997
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Observations were made in workers by the company physician; limited reporting.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
1995

Materials and methods

Type of sensitisation studied:
skin
Study type:
case report
Test guideline
Qualifier:
no guideline required
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent

Method

Type of population:
occupational

Results and discussion

Any other information on results incl. tables

Based on the survey, it was concluded that several workers exposed to Perkalink 900 showed complaints and reactions pointing at sensitisation. Following installment of safety measures, the number of complaints related to sensitisation decreased.

Applicant's summary and conclusion

Conclusions:
Based on complaints in workers it was concluded that Perkalink 900 is a sensitiser in humans.