Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 1992 - January 1993
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Well conducted study according to GLP
Cross-reference
Reason / purpose:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1993
Report Date:
1993

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Principles of method if other than guideline:
The following was measured:
- flash point (closed): according to BS6664 part 5 (Pensky-Martens closed cup)
- flash point (open) and fire point: according to BS2000 (Pensky-Martens open tester)
GLP compliance:
yes
Type of method:
other: see below

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Batch no 910312

Results and discussion

Flash pointopen allclose all
Flash point:
> 360 °C
Atm. press.:
771.1 mm Hg
Remarks on result:
other: closed
Flash point:
257 °C
Atm. press.:
771.1 mm Hg
Remarks on result:
other: open
Flash point:
284 °C
Atm. press.:
771.1 mm Hg
Remarks on result:
other: fire point

Applicant's summary and conclusion