Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 1990-06-07 to 1990-06-08
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP and guideline compliant study.
Cross-referenceopen allclose all
Reason / purpose:
reference to same study
Reason / purpose:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1990
Report Date:
1990

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
April 25th 1984
Deviations:
no
Principles of method if other than guideline:
NA
GLP compliance:
yes
Type of method:
static method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
26.9 mBar
Remarks on result:
other: no remarks
Temp.:
35 °C
Vapour pressure:
39.3 mBar
Remarks on result:
other: no remarks

Any other information on results incl. tables

no remarks

Applicant's summary and conclusion

Conclusions:
The vapour pressure is 29.9 mBar at 20°C.
Executive summary: