EC number: 203-180-0 | CAS number: 104-15-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Particle size distribution (Granulometry)
Administrative data
Link to relevant study record(s)
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- August 2010
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- comparable to guideline study with acceptable restrictions
- Guideline:
- other: Quality manual P17 - AKP 533. Light scattering
- Principles of method if other than guideline:
- Quality manual P17 - AKP 533. Light scattering
Instrument:
Horiba Partica LA-950 (measurement range from 10 nm to 3000 μm)
Conditions of measurement:
Fraction cell
Refractive index of sample: 1.600 – 0.000i
Refractive index of dispersant: 1.460 (paraffinum perliquidum)
Transmittance (R): 96 – 80%
Transmittance (B): 98 – 84%
Sample preparation:
A small amount of the sample was inserted in the 25 ml beaker; approximately 10 ml of paraffinum perliquidum was added and dispersed for 1 minute in the ultrasonic tank. Particle size distribution was measured at conditions described above. The whole measuring procedure was repeated for five times. Average value was computed from the resulting values. The value nearest to average was used as final result of the test. - GLP compliance:
- no
- Type of method:
- Laser scattering/diffraction
- Type of distribution:
- volumetric distribution
- Percentile:
- D50
- Mean:
- ca. 346.7 µm
- Remarks on result:
- not measured/tested
- Remarks:
- Std Dev not reported
- Percentile:
- D10
- Mean:
- ca. 163 µm
- Remarks on result:
- not measured/tested
- Remarks:
- Std Dev not reported
- Percentile:
- D90
- Mean:
- ca. 660.8 µm
- Remarks on result:
- not measured/tested
- Remarks:
- Std Dev not reported
- Conclusions:
- Mass median diameter: 346.7 um
Reference
Results:
For indication of the particle size statistical value was used:
Median Size - is the value, which divides the population exactly two equal halves (i.e. there is 50% of the distribution above this value and 50% below).
Diameter on Cumulative 10%: 10% of particle is less then this value
Diameter on Cumulative 90%: 90% of particle is less then this value
Span
Diameter on cumulative 90% – Diameter on cumulative 10%
Span = --------------------------------------------------------------------------------
Median
Extended uncertainty of determination of the median is 10 %.
Extended uncertainty was calculated by using coefficient 2 (for normal distribution agrees with probability of coverage about 95%).
Description of key information
Mass median diameter: 346.7 um
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.