Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The test method is scientifically according to guideline test, and the report was well organized and fully presented.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ISO 13320-1:2009
GLP compliance:
no
Type of distribution:
other: Laser scatter

Test material

Constituent 1
Chemical structure
Reference substance name:
N,N',N'',N'''-tetrakis(4,6-bis(butyl-(N-methyl-2,2,6,6-tetramethylpiperidin-4-yl)amino)triazin-2-yl)-4,7-diazadecane-1,10-diamine
EC Number:
401-990-0
EC Name:
N,N',N'',N'''-tetrakis(4,6-bis(butyl-(N-methyl-2,2,6,6-tetramethylpiperidin-4-yl)amino)triazin-2-yl)-4,7-diazadecane-1,10-diamine
Cas Number:
106990-43-6
Molecular formula:
C132H250N32
IUPAC Name:
N,N',N'',N'''-tetrakis(4,6-bis(butyl-(N-methyl-2,2,6,6-tetramethylpiperidin-4-yl)amino)triazin-2-yl)-4,7-diazadecane-1,10-diamine

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Mean:
1.05 - 200.06 µm
Remarks on result:
other: Determination range of the test is 0.1-340 μm.(migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.)
Percentile:
D10
Mean:
14.56 µm
St. dev.:
1.19
Percentile:
D50
Mean:
42.47 µm
St. dev.:
3.82
Percentile:
D90
Mean:
78.74 µm
St. dev.:
5.95

Applicant's summary and conclusion

Conclusions:
Granulometry : 42.47μm (D50)