Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
from 8 March 2021 to 11 May 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2016
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Remarks:
certificate dated from 18 September 2019
Type of method:
closed cup
Remarks:
Pensky-Martens closed cup Method
Key result
Flash point:
120 °C
Atm. press.:
101 325 Pa
Conclusions:
The flash point of Cyclamen Aldehyde Extra was determined by the Pensky-Martens closed cup method according to ISO standard 2719. The result is 120 °C
Executive summary:

The flash point of Cyclamen Aldehyde Extra was determined by the Pensky-Martens closed cup method according to ISO standard 2719.

The result is 120 °C

Description of key information

Flash point 120 °C (ISO 2719, EU method A9)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
120 °C

Additional information

The flash point of Cyclamen Aldehyde Extra was determined by the Pensky-Martens closed cup method according to ISO standard 2719. The result is 120°C.