Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Testing was conducted between 14 February 2008 and 31 March 2008.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
The work described was performed in compliance with UK GLP standards (Schedule 1, Good Laboratory Practice Regulations 1999 (SI 1999/3106 as amended by SI 2004/0994)). Date of inspection: 21/08/2007. Date of signature: 23/04/2008.
Type of method:
HPLC estimation method
Media:
other: methanol

Test material

Constituent 1
Details on test material:
Sponsor's identification :Hatcol 1760
Description : clear colourless slightly viscous liquid
Purity : >99%
Date received : 04 February 2008
Storage conditions :room temperature, in the dark
Radiolabelling:
no

Study design

Test temperature:
40°C

HPLC method

Details on study design: HPLC method:
EQUIPMENT
- Apparatus: HPLC
- Type: Agilent Technologies 1100, incorporating autosampler and workstation
- Type, material and dimension of analytical (guard) column: Zorbax SB-CN 5µm (250 x 4.6 mm id)
- Detection system: UV - dead time and reference standards: 210 nm
sample: 210 nm


MOBILE PHASES
- Type:
- Experiments with additives carried out on separate columns: no
- pH: 6.4
- Solutes for dissolving test and reference substances: methanol


DETERMINATION OF DEAD TIME
- Method: by means of homologous series.


REFERENCE SUBSTANCES
- Identity: Acetanilide, Phenol, Atrazine, Isoproturon, Triadimenol, Linuron, Naphthalene, Endosulfan-diol, Fenthion, alpha-Endosulfan, Phenanthrene, Diclofop-methyl, DDT


DETERMINATION OF RETENTION TIMES
- Quantity of test substance introduced in the column: 25 µl
- Quantity of reference substances: 25 µl
- Intervals of calibration:

As the test material had a high affinity for the stationary phase of the column, the mobile phase was ramped to 100% acetonitrile shortly after the retention time of DDT, to elute the sample.

REPETITIONS
- Number of determinations: duplicate (x2)


EVALUATION
- Calculation of capacity factors k':
The capacity factor was determined using the following equation:

K = (tr – to) / to
where:
k = capacity factor
tr = retention time (min)
t0 = dead time (min)


- Calculation of retention times: not stated in report.

- Determination of the log Koc value:
The adsorption coefficient was calculated using the following equation:
Log10 Koc = (Log10 k – A) / B

where:
Koc = adsorption coefficient
k = capacity factor
A = intercept of the calibration curve
B = slope of the calibration curve

Results and discussion

Adsorption coefficientopen allclose all
Type:
Koc
Value:
> 427 000
Type:
log Koc
Value:
> 5.63

Results: HPLC method

Details on results (HPLC method):
- Retention times of reference substances used for calibration: Please see section "Remarks on results including tables and figures"

- Details of fitted regression line: Log k' vs. log Koc

- Graph of regression line attached: Yes

- Average retention data for test substance: 40 minutes

Any other information on results incl. tables

Calibration

The retention times of formamide and the retention times, capacity factors (k) and log10Kocvalues for the reference standards are shown in the two following tables:

Dead Time

Retention Time (mins)

Mean Retention Time (mins)

Injection 1

Injection 2

Formamide

2.797

2.797

2.797

Standard

Retention Time (mins)

Mean Retention Time (mins)

Capacity Factor (k)

Log10k

Log10Koc

Injection 1

Injection 2

Acetanilide

3.715

3.715

3.715

0.328

-0.484

1.25

Phenol

3.551

3.552

3.552

0.270

-0.569

1.32

Atrazine

5.176

5.175

5.176

0.850

-7.04 x 10-2

1.81

Isoproturon

5.413

5.412

5.413

0.935

-2.91 x 10-2

1.86

Triadimenol

6.956

6.953

6.955

1.49

0.172

2.40

Linuron

7.235

7.236

7.236

1.59

0.201

2.59

Naphthalene

6.358

6.359

6.359

1.27

0.105

2.75

Endosulfan-diol

8.355

8.355

8.355

1.99

0.298

3.02

Fenthion

10.637

10.639

10.638

2.80

0.448

3.31

a-Endosulfan

14.649

14.651

14.650

4.24

0.627

4.09

Phenanthrene

12.287

12.290

12.289

3.39

0.531

4.09

Diclofop-methyl

16.371

16.385

16.378

4.86

0.686

4.20

DDT

31.873

31.881

31.877

10.4

1.02

5.63

Adsorption coefficient of sample

The retention times, capacity factors and log10Kocvalues determined for the sample are shown in the following table:

Injection

Retention Time (mins)

Capacity Factor (k)

Log10k

Log10Koc

1

40.355

>10.4

>1.02

>5.63

2

40.357

>10.4

>1.02

>5.63

Mean log10Koc:                       >5.63
Adsorption coefficient: >4.27 x 105

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Conclusions:
The adsorption coefficient (Koc) of the test material has been determined to be >4.27 x 105, log10 Koc >5.63.
Executive summary:

Method

The determination was carried out using the HPLC screening method, Method C19 of Commission Directive 2001/59/EC (which constitutes Annex V of Council Directive 67/548/EEC).

Conclusion

The adsorption coefficient (Koc) of the test material has been determined to be >4.27 x 105, log10 Koc >5.63.