Registration Dossier

Administrative data

First-aid measures

Exposure by inhalation: Remove to fresh air and seek medical advice.

Exposure by skin contact: Wash with soap and water thoroughly. Seek medical advice if necessary. Remover contaminated clothing.

Exposure by eye contact: Flush with water for 15 minutes. Seek medical advice.

Exposure by ingestion: Do not induce vomiting. Drink plenty of water. Do not give anything to an unconcious vistim. Seek medical advice immediately.

Fire-fighting measures

Suitable extinguishing media: Foam, carbon dioxide, dry chemical. Use water spray to cool surface of container.

Extinguishing media not to be used: None.

Specific exposure hazards: Avoid contact with fire and sparks.

Protective equipment for fire-fighters: Use self-contained breathing apparatus. Avoid breathing fumes, vapours or mists. Water may cause frothing.

Accidental release measures

Personal precautions: Avoid skin and eye contact. Do not breathe vapour. Use neoprene gloves, chemical splash goggles and use an approved (NIOSH) organic cartridge vapour respirator.

Environmental precautions: Avoid release to the environment.

Methods for cleaning up: dike or contain spill. Apply suitable absorbent. Put in container. Close container. Prevent from entering sewer and waterways. notify proper authorities.

Handling and storage

Precautions: The substance should be handled under conditions of good industrial hygiene and in conformity with local regulations in order to avoid unnecessary exposure.

Technical measures: engineering controls such as local exhaust ventilation should be used in order to minimise exposure to the substance.

Storage
Specific design for storage rooms or vessels: The substance is stored in isotanks of mild steel constructipn fitted with silica gel breathers to prevent the ingress of atmospheric moisture.
Conditions of storage: Store in a cool, dry place.
Quantity limits: None
Packaging materials: Mild steel isotanks.

Transport information

Land transport (ADR/RID)

UN number:
Not classified for land transport by road or rail.
Shippingopen allclose all
Class:
Not applicable
Classification code:
Not applicable
Packaging group:
Not applicable
Labels:
Not applicable
SpecialProvisionsopen allclose all

Inland waterway transport (ADN(R))

UN number:
Not classified for transport by inland waterway.
Shippingopen allclose all
Class:
Not applicable
Classification code:
Not applicable
Packaging group:
Not applicable
Labels:
Not applicable
Remarksopen allclose all

Marine transport (IMDG)

UN number:
Not classified for marine transport.
Proper shipping name and description:
Not applicable
Chemical name:
Not applicable
Class:
Not applicable
Packaging group:
Not applicable
EmS code:
Not applicable
Labels:
Not applicable
Remarksopen allclose all

Air transport ICAO/IATA

UN number:
Not classified for transport by air.
Proper shipping name and description:
Not applicable
Chemical name:
Not applicable
Class:
Not applicable
Packaging group:
Not applicable
Labels:
Not applicable
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Local exhaust ventilation used.

Respiratory protection: The use of a vapour mask to a minimum standard of EN405 FFA1 is recommended.

Hand protection: Chemical protective gloves to a Standard EN374 should be provided. Usage periods should not exceed the breakthrough times for the chemical stated by the manufacturer of the glove.

Eye protection: Eye protection should be used when handling the substance. The protection should be capable of giving chemical protection as classified in EN166.

Skin protection: Handling of the material should be done wearing chemical protective clothing suitable for protection against the chemical as classified by standard EN368.

Stability and reactivity

Conditions to avoid: High temperatures
Incompatible materials: Strong acids, bases or strong oxidisers.
Hazardous decomposition products: Carbon oxides.

Disposal considerations

Waste from residues: Dispose of by incineration or landfill in accordance with local regulations. Stack gasses should be scrubbed.

Contaminated packaging: Dispose of by incineration or landfill in accordance with local regulations. Stack gasses should be scrubbed.