Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
GLP compliance:
no

Test material

Constituent 1
Test material form:
other: liquid

Results and discussion

For thermal stability study

Test substance thermally stable:
yes
Operating temperature
Operating temp.:
500 °C
Remarks on result:
other: The safe handling temperature of the test item is T(exo) = 400 °C.

Applicant's summary and conclusion

Conclusions:
The safe handling temperature of the substance is T(exo) = 400 °C.
Executive summary:

The safe handling temperature of the substance was determined to be T(exo) = 400 °C.