Registration Dossier

Environmental fate & pathways

Hydrolysis

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The test item was found to be stable in the preliminary test (OECD 111) at pH 4, 7 and 9 at 50 °C (Table 1). Reaction rate constants and half-lives could not be calculated due to the fact that the test item undergoes no significant hydrolysis. According to the guideline a half-life of > 1 year under environmental conditions can be assumed.

Key value for chemical safety assessment

Additional information

The test item was found to be stable in the preliminary test (OECD 111) at pH 4, 7 and 9 at 50 °C (Table 1). Reaction rate constants and half-lives could not be calculated due to the fact that the test item undergoes no significant hydrolysis. According to the guideline a half-life of > 1 year under environmental conditions can be assumed.