Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10/06/2009 – 11/06/2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Remarks:
Pensky-Martens closed cup apparatus
Atm. press.:
other: the approximately 215°C fire-point no flash observed therefore, testing was terminated.
Remarks on result:
other: No flash observed; the fire-point was reached at approximately 215°C therefore testing was terminated.

No flash observed; the fire-point was reached at approximately 215°C therefore testing was terminated. It was suspected the sample started to decompose at approximately 175°C as the temperature reading started to fluctuate and small amounts of grey vapour were produced.

Interpretation of results:
GHS criteria not met
Conclusions:
No flashpoint observed; the fire-point was reached at approximately 215°C therefore testing was terminated. It was suspected the sample started to decompose at approximately 175°C as the temperature reading started to fluctuate and small amounts of grey vapour were produced.

Description of key information

No flash observed; the fire-point was reached at approximately 215°C therefore testing was terminated. It was suspected the sample started to decompose at approximately 175°C as the temperature reading started to fluctuate and small amounts of grey vapour were produced.

Key value for chemical safety assessment

Additional information