Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
equivalent or similar to guideline
Guideline:
other: ASTM D-86
GLP compliance:
no
Type of method:
distillation method
Specific details on test material used for the study:
Product ID: 2-ethyl-2-oxazoline (ETOX from Alvin, TX)
Matrix type: Liquid
Key result
Boiling pt.:
131 °C
Atm. press.:
1 atm
Remarks on result:
other: Initial Boiling Point reported as 268 °F
Conclusions:
The test material has a boiling point of 131 °C (268 °F).
Executive summary:

This value agrees with experience during use and handling.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Qualifier:
no guideline followed
Principles of method if other than guideline:
Measured values are reported with no details regarding methodology.
GLP compliance:
not specified
Type of method:
other: Not specified
Boiling pt.:
128 °C
Atm. press.:
1 atm
Conclusions:
The test material has a boiling point of 128 °C.
Executive summary:

This value agrees with experience during use and handling.

Description of key information

The boiling point is experimentally measured to be 131 °C.

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
131 °C

Additional information

The boiling point is experimentally measured to be 131 °C. This conclusion is supported by the Petroleum Labs, Inc. measured initial boiling point of 131 °C and the Kobayashi, S. and Saegusa, T. reference value of 128 °C. Additionally, a value of 131 °C agrees with manufacturing experience.

The Zedi US Inc. study is disregarded. Values reported disagree with experience during manufacturing and use. Also, the value disagrees with secondary reference values and the subsequent re-testing of the material.