Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: well performed study according to acknowledged standard

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report date:
2014

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ISO 13320 -1
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
1,4-bis(butylamino)anthraquinone
EC Number:
241-379-4
EC Name:
1,4-bis(butylamino)anthraquinone
Cas Number:
17354-14-2
Molecular formula:
C22H26N2O2
IUPAC Name:
1,4-bis(butylamino)anthraquinone
Details on test material:
Purity: 98.8 % (w/w)
Expiry Date: 18.01.2020

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Mean:
12 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
3.2 µm
St. dev.:
0.1
Percentile:
D50
Mean:
12.6 µm
St. dev.:
1.6
Percentile:
D90
Mean:
66 µm
St. dev.:
16

Applicant's summary and conclusion

Conclusions:
The mass median diameter of the particle size distribution of the substance is 12.6 µm.
Executive summary:

The particle size distribution of the substance was determined by laser diffraction using a ;alvern Mastersizer equipment. The mass median diameter D50 was found to be 12.6 µm.