Registration Dossier

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The test was performed according to an industry accepted guideline.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2009
Report Date:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: ASTM D445-97 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids 9the Calculaiton of Dynamic Viscosity)
Deviations:
no
GLP compliance:
no
Remarks:
ISO 9001/2000 Certified
Type of method:
capillary viscometer (static)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Viscosityopen allclose all
Temp.:
other: 100.0°C
Parameter:
other: cSt
Value:
13.5
Temp.:
40°C
Parameter:
other: cSt
Value:
407.6

Applicant's summary and conclusion

Conclusions:
Following the method in ASTM D445-97, the viscosity of the test substance was determined to be 13.5 cSt at 100 C and 407.6 cSt at 40 C.
Executive summary:

Following ASTM D445-97 guidelines, the viscosity of the test substance was determined to be 13.5 cSt at 100 deg. C and 407.6 cSt at 40 deg. C.