Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 915-093-1 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Eyes- Rinse opened eye for several minutes under running water. Consult a doctor if required.
Inhalation-Remove to fresh air. Seek medical attention if required.
Skin-Immediately wash with soap and water and rinse thoroughly. Seek medical attention if required.
General advice-After first aid, get appropriate medical attention. In general, metal powders or dust may cause mechanical eye and skin irritation. Inhalation of powder or dust may cause mild respiratory tract irritation.
Fire-fighting measures
Substance is non-flammable. Extinguishing methods depend upon hazards in vicinity. Use water or dry extinguishing powders, sand, CO2 or other inert material as extinguishing media. Do not use water if any water-reactive metal powders are nearby.No hazardous decomposition products are known. Firefighters-Use a self-contained breathing apparatus and a protective suit.
Accidental release measures
Use personal protective equipment (i.e. gloves, safety goggles, dust respirator) as specified in Exposure Controls below.
Avoid release into the environment.
Use clean-up methods which avoid dust generation, such as vacuuming (with filter that prevents re-suspension of dust) or wet clean-up, and fill into appropriate sealable containers. Clean remaining spills with water. Dispose of wastes according to regulations.
Handling and storage
Ensure adequate ventilation and, if necessary, exhaust ventilation when handling or transferring this material. Use good housekeeping procedures to prevent accumulation of dust and ensure that accepted limit values are complied with. Wear personal protective equipment when handling.
Store in tightly closed containers in a well ventilated area. Store under dry and cool conditions, and away from incompatible materials (oxidising agents and acids).
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Engineering controls may include local ventilation systems with dust filters depending on degree of process automation and containment
Eye protection-Use of safety glasses as appropriate and reasonably necessary, depending on degree of process automation and containment.
Skin protection- Use of work gloves and work clothes as appropriate and reasonably necessary, depending on degree of process automation and containment.
Respiratory protection-Use of respiratory protection as appropriate and reasonably necessary, depending on degree of process automation and containment.
Stability and reactivity
No hazardous reactions known.
Stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
Avoid formation and accumulation of dust.
No possibility of hazarous reactions, incompatible materials or decomposition products known.
Disposal considerations
Waste Management Controls:
Dispose in accordance with local/regional/national/international regulations. Two options are recommended:
1. Re-use
2. Recycling or other recovery
Wastewater should be processed through a sewage treatment plant (STP) either on-site or off-site.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.