Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
december 2007 to juanuary 2008
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Principles of method if other than guideline:
The item is formed into an unbroken strip or powder train about 250-mm long and a preliminary screening test performed to determine if, on ignition by a gas flam, propagation by burning with flame or smouldering occurs. If propagation over 200 mm of the train occurs within a specified time then a full test programme to determined the burning rate is carried out.
Paste-like test item are spread on a non-combustible, non-porous and low heat-conducting base plate in the form of a rope 250-mm in length with a cross section of about 1 cm2.
GLP compliance:
yes (incl. QA statement)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flammable gases (Lower and upper explosion limit)open allclose all
Parameter:
lower explosion limit
Value:
ca. 0 % (not further specified)
Parameter:
upper explosion limit
Value:
ca. 0 % (not further specified)
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

Taking into account the results obtained during the preliminary test, no main test was performed.

Applicant's summary and conclusion

Conclusions:
The test item was not considered as hignly flammable under our experimental conditions.
Executive summary:

The test item was not considered as hignly flammable under our experimental conditions.