Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 - 13 September 2006
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
0 s
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

The pile failed to ignite during the two minutes that the Bunsen flame was applied. The result of the preliminary screening test obviated the need to perform the main test.

The moisture content of ca. 1 g test material is ca. 0.12% (w/w).

Interpretation of results:
non flammable
Conclusions:
The test substance has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.

Description of key information

The test substance has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification