Registration Dossier

Environmental fate & pathways

Endpoint summary

Administrative data

Description of key information

Additional information

The three key studies are assigned a reliability of 1 (reliable without restriction), are in accordance with GLP and are considered valid.

Biodegradation: The test material attained 30% degradation after 28 days and therefore cannot be considered readily biodegradable under the strict terms and conditions of OECD Guideline No 301B. Not readily biodegradable-unlikely to undergo rapid biodegradation in the environment.

Stability in water: Low level of hydrolysis at acidic and basic pH and high mobility in soil.

- Hydrolysis (50 C, pH 4 -9): Half-life: > 365 days, Low level of hydrolysis at acidic and basic pH.

- Adsorption coefficient: Koc ( Estimation by HPLC): < 17.8. High Mobility in soil.

The one key study was assigned a reliability of 1 (reliable without restriction), was in accordance with GLP and considered valid.