Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
26-Dec-2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Remarks:
Certificat de conformite aux bonnes pratiques de laboratoire selon les directives 2004/9/CE et 2004/10/CE
Type of method:
equilibrium method closed cup
Flash point:
43.5 °C
Atm. press.:
1 013 hPa

Preliminary test

Atmospheric pressure 97.7 kPa

Relative humidity: About 38%

 

Temperature (°C)

 

Observed

temperature

(OT)

Corrected

temperature with the

calibration curve (CT)

Corrected to Patm

(C)

Flash

observation

50.7

49.0

50.0

Yes

40.3

39.0

40.0

No

45.5

44.0

45.0

Yes

 

The flash point was observed between 40.0°C and 45.0°C (corrected values).

Main test

Atmospheric pressure 97.8 kPa

Relative humidity: About 36%

 

Temperature (°C)

 

Observed

temperature

(OT)

Corrected

temperature with the

calibration curve (CT)

Corrected to Patm

(C)

Flash

observation

40.3

39.0

40.0

No

40.8

39.5

40.5

No

41.4

40.0

41.0

No

41.9

40.5

41.5

No

42.4

41.0

42.0

No

42.9

41.5

42.5

No

43.4

42.0

43.0

No

43.9

42.5

43.5

Yes

 

Conclusion

The flash point of the test item was 43.5°C ± 0.5°C (corrected value).

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
A flash point value of 43.5 +/-0.5 °C at 1013 hPa was determined in a reliable study conducted according to an appropriate test protocol.

Description of key information

Hexyl(trimethoxy)silane: 43.5 +/- 0.5 °C at 1013 hPa (equilibrium method closed cup, EU method A.9)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
43.5 °C

Additional information