Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
Lot Number: 161217

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
> 4 min

Any other information on results incl. tables

Sample melted and a localised orange flame occurred where the test flame was in contact. The orange flame extinguished as soon as the test flame was removed.

From the preliminary screening test the sample was seen to burn in a time > 4 minutes and therefore no further testing is required.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The substance is not classified as flammable.