Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11.11.2014 to 18.11.2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: UN N.1 Test
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Potassium 2-methylbutan-2-olate
EC Number:
255-272-5
EC Name:
Potassium 2-methylbutan-2-olate
Cas Number:
41233-93-6
Molecular formula:
C5H12O.K
IUPAC Name:
potassium 2-methylbutan-2-olate
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
< 45 s

Any other information on results incl. tables

Due to the fact that the burning time was faster than 45 s, the test item is highly flammable in the

sense of the European Commission Regulation (EC) No. 440/2008, Method A.1 0.

Due to the fact that the burning time was faster than 45 s and the flame passed the wetted zone, the

test item has to be classified as flammable solid, class 4.1, packing group II, of the

Recommendations on the Transport of Dangerous Goods I Manual of Tests and Criteria.

Due to the fact that the burning time was faster than 45 s and the flame passed the wetted zone, the

test item has to be classified as flammable solid, category 1, according to chapter 2.71 of the GHS

(CLP) regulations.

Applicant's summary and conclusion

Interpretation of results:
flammable
Remarks:
Migrated information see the Conclusion
Conclusions:
Due to the fact that the burning time was faster than 45 s, the test item is highly flammable in the
sense of the European Commission Regulation (EC) No. 440/2008, Method A.10.
Due to the fact that the burning time was faster than 45 s and the flame passed the wetted zone, the
test item has to be classified as flammable solid, class 4.1, packing group II, of the
Recommendations on the Transport of Dangerous Goods I Manual of Tests and Criteria.
Due to the fact that the burning time was faster than 45 s and the flame passed the wetted zone, the
test item has to be classified as flammable solid, category 1, according to chapter 2.71 of the GHS
(CLP) regulations.

Due to the fact that the burning time was faster than 45 s and the flame passed the wetted zone, the
test item has to be classified as flammable solid, class 4.1, packing group II, of the
Recommendations on the Transport of Dangerous Goods I Manual of Tests and Criteria.

Due to the fact that the burning time was faster than 45 s and the flame passed the wetted zone, the
test item has to be classified as flammable solid, category 1, according to chapter 2.71 of the GHS
(CLP) regulations.
Executive summary:

Due to the fact that the burning time was faster than 45 s, the test item is highly flammable in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10. Due to the fact that the burning time was faster than 45 s and the flame passed the wetted zone, the test item has to be classified as flammable solid, class 4.1, packing group II, of the Recommendations on the Transport of Dangerous Goods I Manual of Tests and Criteria. Due to the fact that the burning time was faster than 45 s and the flame passed the wetted zone, the test item has to be classified as flammable solid, category 1, according to chapter 2.71 of the GHS (CLP) regulations.