Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
GLP compliance:
yes (incl. certificate)
Key result
Parameter:
other: not possible
Remarks on result:
not determinable
Key result
Sample tested:
other: not specified (migrated information)not an oxidising solid
Parameter:
other: not an oxidising solid
Remarks on result:
not determinable
Key result
Sample tested:
other: not specified (migrated information)not an oxidising solid
Parameter:
other: not an oxidising solid
Remarks on result:
vigorous reaction in the preliminary test
Preliminary screening test
Composition of 2:1 Ratio Mass of material (g) Type of reaction Burning time (sec) Comments on burning behaviour
Reference sample 3 vigorous 8 vigorous reaction
Cellulose 2
Test sample 2 none 0 no reaction
Cellulose 1

From the preliminary screening test, the sample did not ignite and no reaction was observed. Therefore, the sample is not considered an oxidiser and no further testing is required.

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Executive summary:

Results : Not an oxidising solid

Description of key information

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification