Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011

Materials and methods

Test guideline
Qualifier:
no guideline followed
Guideline:
other: Instrument determination
Type of method:
other: Other

Test material

Constituent 1
Chemical structure
Reference substance name:
Ammonium iodide
EC Number:
234-717-7
EC Name:
Ammonium iodide
Cas Number:
12027-06-4
Molecular formula:
H4IN
IUPAC Name:
ammonium iodide
Test material form:
solid

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Mean:
ca. 211 µm
St. dev.:
0.002
Percentile:
D10
Mean:
ca. 85 µm
St. dev.:
0.003

Any other information on results incl. tables

The particle size distribution (in volume) is characterized by a wide peak at around 230µm. The minimal size is equal to 4.5µm and the maximal size is 800µm. There are 13.9% of particles with a size less than 100µm.

Applicant's summary and conclusion

Conclusions:
Granulometry: 221.6 µm (median diameter by volume)