Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 227-876-9 | CAS number: 6021-61-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Water solubility
Administrative data
Link to relevant study record(s)
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- February from 09th to 21st, 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 105 (Water Solubility)
- Version / remarks:
- adopted July 27, 1995
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- column elution method
- Water solubility:
- 94 µg/L
- Conc. based on:
- test mat.
- Temp.:
- 20 °C
- pH:
- 7.2
- Details on results:
- The water solubility of test item was determined to be 0.094 ± 0.00924 mg/l (95 % confidence interval) at 20 ± 0.5 °C using the column elution method for the performance of the main test.
The measured concentrations are constant within ± 30 % and thus within the range required by the guidelines. - Conclusions:
- Water solubility: 94 µg/l at 20 °C and pH ca 7.20
- Executive summary:
The purpose of the study was to evaluate the solubility of test item in water at 20 ± 0.5 °C, according to the OECD guideline 105. The method chosen is based on the elution of the test substance with water from a micro-column, which is charged with an inert support material coated with an excess of test substance. The water solubility is determined when the mass concentration of the eluate is constant, i.e. concentration plateau as a function of time.
The water solubility of test item was determined to be 0.094 ± 0.00924 mg/l (95 % confidence interval) at 20 ± 0.5 °C using the column elution method for the performance of the main test. The measured concentrations are constant within ± 30 % and thus within the range required by the guidelines.
Conclusion
Water solubility: 94 µg/l at 20 °C and pH ca 7.20.
Reference
Results of the determination of water solubility of test item (flow rate: ca. 25 ml/hour)
Measured concentration (mg/l) | |||
Column 1 | Column 2 | ||
below the quantitation limit | pH = 7.44 | below the quantitation limit | pH = 7.31 |
below the quantitation limit | pH = 7.42 | below the quantitation limit | pH = 7.28 |
below the quantitation limit | pH = 7.45 | below the quantitation limit | pH = 7.29 |
0.0622 | pH = 7.40 | 0.0665 | pH = 7.27 |
0.0701 | pH = 7.38 | 0.0695 | pH = 7.31 |
0.0961 | pH = 7.23 | 0.0989 | pH = 7.20 |
0.0977 | pH = 7.19 | 0.1139 | pH = 7.21 |
0.0939 | pH = 7.15 | 0.0978 | pH = 7.18 |
0.0888 | pH = 7.07 | 0.0958 | pH = 7.15 |
Mean / RDS: 0.0876 / 19 % | |||
pH 7.22 - 7 -24 |
Results of the determination of water solubility of test item (flow rate: ca. 12.5 ml/hour)
Measured concentration (mg/l) | |||
Column 1. | Column 2. | ||
0.0978 | pH = 7.19 | 0.1070 | pH = 7.23 |
0.1088 | pH = 7.20 | 0.1080 | pH = 7.18 |
0.1221 | pH = 7.20 | 0.1215 | pH = 7.21 |
0.0916 | pH = 7.17 | 0.1055 | pH = 7.18 |
0.1072 | pH = 7.13 | 0.0891 | pH = 7.15 |
0.0961 | pH = 7.14 | 0.1118 | pH = 7.16 |
0.0759 | pH = 7.10 | 0.0699 | pH = 7.09 |
0.0830 | pH = 7.10 | 0.0869 | pH = 7.09 |
Mean / RDS: 0.0989 / 15 % | |||
pH 7.15 - 7 .16 |
Description of key information
94 µg/l at 20 °C and pH ca. 7.20
Key value for chemical safety assessment
- Water solubility:
- 94 µg/L
- at the temperature of:
- 20 °C
Additional information
OECD 105 - column elution method
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.