Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The test is technically not feasible since the self-accelerating decomposition temperature (SADT) of the substance is +20 °C.

Key value for chemical safety assessment

Additional information

Test method EU A.15 is not applicable because the substance decomposes under the test conditions. The self-accelerating decomposition temperature (SADT) of the substance is 20 °C (reference SADT: CLP regulations 2.15.2.3 and UN Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, 5th revised edition, sub-sections 28.1, 28.2, 28.3 and Table 28.3.).

Also see ECHA guidance on the application of the CLP criteria, section 2.14.