Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
not specified
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Remarks:
Valid with restrictions. This is peer reviewed data where the test methodology and identity of the substance have been evaluated, and a reliable and representative value for the endpoint has been selected. No information on GLP status or test guideline followed is available.
Qualifier:
no guideline followed
Principles of method if other than guideline:
Handbook data does not specify the method. Data from peer reviewed source.
GLP compliance:
not specified
Type of method:
closed cup
Key result
Flash point:
-2 °C
Remarks on result:
other: no information on atm. pressure
Interpretation of results:
other: Category 2 (highly flammable liquids) according to EU criteria
Conclusions:
According to the handbook data the flash point of the substance is -2 °C.
Executive summary:

According to the handbook data the flash point of the substance is -2 °C.

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
not specified
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Remarks:
Valid with restrictions. This is peer reviewed data where the test methodology and identity of the substance have been evaluated, and a reliable and representative value for the endpoint has been selected. No information on GLP status or test guideline followed is available.
Qualifier:
no guideline followed
Principles of method if other than guideline:
Handbook data does not specify the method. Data from peer reviewed source.
GLP compliance:
not specified
Type of method:
other: Handbook data does not specify the method. Data from peer reviewed source.
Key result
Flash point:
-2 °C
Remarks on result:
other: no information on atm. pressure
Interpretation of results:
other: Category 2 (highly flammable liquids) according to EU criteria
Conclusions:
According to the handbook data the flash point of the substance is -2 °C.
Executive summary:

According to the handbook data the flash point of the substance is -2 °C.

Description of key information

Sax's Handbook

According to the handbook data the flash point of the substance is -2 °C.

Merck Index

According to the handbook data the flash point of the substance is -2 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
-2 °C

Additional information

Sax's Handbook

According to the handbook data the flash point of the substance is -2 °C.

Merck Index

According to the handbook data the flash point of the substance is -2 °C.