Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
no
Specific details on test material used for the study:
Charge-No.: 12128E71
BTS internal sample no: 113465
Auto-ignition temperature:
370 °C
Atm. press.:
1 013 hPa
Remarks on result:
other:
Conclusions:
The self-ignition temperature was determined to be at 370°C at 1013 hPa.
Executive summary:

The self-ignition temperature was determined with the EU-Method A.15 to be at 370°C at 1013 hPa.

Description of key information

The self-ignition temperature was determined to be at 370°C at 1013 hPa.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
370 °C

Additional information