Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Version / remarks:
DIN EN 14522
GLP compliance:
no
Auto-ignition temperature:
423 °C
Atm. press.:
1 013.25 hPa
Conclusions:
The autoignition temperture of the test material was determined to be 423°C at 1013.25 hPa under the conditions of the test.