Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002.
Qualifier:
equivalent or similar to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
closed cup
Flash point:
144 °C
Atm. press.:
1 013.25 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test material was determined to be 144°C at 1013.25 hPa under the conditions of the test.

Description of key information

The study was conducted to recognised testing guidelines, and with GLP certification.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
144 °C