Registration Dossier

Diss Factsheets

Environmental fate & pathways

Hydrolysis

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Data on hydrolysis are not available. Due to structural properties and the practically insolubility in water hydrolysis is not expected.

Key value for chemical safety assessment

Additional information

According to Kollig et al. (1993), Boethling & Mackay (2000) and Harris (1990), the test substance is generally resistant to hydrolysis because it does not contain any labile functional groups. Therefore, no study on hydrolysis is performed. Furthermore, in accordance with column 2 of REACH Annex VIII, the hydrolysis test (required in section 9.2.2.1) does not need to be conducted, as the test substance is highly insoluble in water (0.0017 mg/L at 20 °C).