Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011-05-04 and 2011-05-25
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Remarks:
Date of Inspection 2010-07-20; Date of signature 2010-10-29
Type of method:
equilibrium method closed cup
Flash point:
102 °C
Atm. press.:
101.5 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test material was assessed according to EU Method A.9 and was determined to be 101.960 °C kPa at 101.325 kPa, rounded to 102 ± 2 °C.

Description of key information

The flash point of the test material was assessed according to EU Method A.9 and was determined to be 101.960 °C kPa at 101.325 kPa, rounded to 102 ± 2 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
102 °C

Additional information