Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Remarks:
The purity of the test substance was reported to be as received from Akzo Nobel Fibres, Amhem.
Justification for type of information:
Additional documentation, provided within the IUCLID Assessment Reports (Section 13), supports the read-across approach.
Reason / purpose for cross-reference:
read-across: supporting information
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
yes
Remarks:
The test was performed according to a slightly modified OECD test guideline.
GLP compliance:
not specified
Analytical monitoring:
no
Vehicle:
yes
Details on test solutions:
PREPARATION AND APPLICATION OF TEST SOLUTION:
- Method: The test substance was added to the incubation vessels using a stock solution of 1.0 g/L.
- Chemical name of vehicle (organic solvent, emulsifier or dispersant): Deionised water containing no more than 0.01 mg Cu/L and 1 mg/L non-purgeable organic carbon
Test organisms (species):
activated sludge of a predominantly industrial sewage
Details on inoculum:
- Laboratory culture: Secondary activated sludge was obtained from the WWTP Kleefse Waard in Arnhem. The WWTP Kleefse Waard is an activated sludge plant treating industrial waste water of the site Kleefse Waard.
- Preparation of inoculum for exposure: the activated sludge was diluted 5 times in the test. The influent used as substrate and effluent used to dilute the sludge were also obtained from the WWTP Kleefse Waard
Test type:
not specified
Water media type:
freshwater
Limit test:
no
Total exposure duration:
30 min
Test temperature:
20°C
pH:
ranged from 8.7-8.9
Nominal and measured concentrations:
Nominal: 0, 3.1, 6.3, 12.5, 25, 50, 100 mg/L
Details on test conditions:
TEST SYSTEM
- Test vessel: 200 mL Erlenmeyers
- Other: Homogenized activated sludge was incubated in a shaking water bath (100 Hz, 20°C) for 30 minutes.

TEST CONCENTRATIONS
- Spacing factor for test concentrations: 2
Reference substance (positive control):
no
Duration:
30 min
Dose descriptor:
other: 30% reduction in respiration rate
Effect conc.:
100 mg/L
Nominal / measured:
nominal
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Remarks on result:
other: EC50 could not be calculated
Details on results:
The validity of the test is shown by the control respiration rates which are within 16% of each other. The respiration rates and inhibition percentages calculated are in Table 1. At 100 mg/L, a 30% reduction of the respiration rate was observed and EC50 values could therefore not be calculated.

Respiration Rates, Inhibition Percentages, pH

Concentration (mg/L)

Activity

(mg O2/min.litre)

Inhibition

(%)

pH

Control

0.31

-

8.7

Control

0.26

-

8.7

3.1

0.31

0

8.7

6.3

0.28

2

8.7

12.5

0.29

0

8.7

25

0.27

5

8.7

50

0.28

2

8.8

100

0.20

30

8.9

Validity criteria fulfilled:
yes
Conclusions:
At 100 mg test substance/L, a 30% reduction of the respiration rate was observed and EC50 values could therefore not be calculated. The test substance will not have any adverse effects on the WWTP Kleefe Waard at concentration <10 mg/L.
Executive summary:

The toxicity of the test substance to activated sludge of the WWTP Kleefse Waard was determined by measuring the respiration rate after a contact time of 30 minutes at various concentrations of the test substance. The inhibitory effect of the test substance at a particular concentration was expressed as a percentage of the two controls. At 100 mg test substance/L, a 30% reduction of the respiration rate was observed and EC50 values could therefore not be calculated. The results demonstrate that the test substance will not have any adverse effects on the WWTP Kleefe Waard at concentration <10 mg/L.

Description of key information

Key value for chemical safety assessment

Additional information

Microbiological respiration inhibition data is provided on p-phenylenediamine in activated sludge of predominantly industrial sewage. A 30% reduction in respiration rate (30 min): 100 mg/L (nominal) based on respiration rate was observed. Additional supporting data is provided for o-phenylenediamine, a structurally related analogue, in activated sludge for predominantly domestic sewage. The EC10 (3 h) and EC50 (3 h) values were 100 mg/L and 580 mg/L respectively. Data from the study with p-phenylenediamine are consistent with the results from the study with o-phenylenediamine.