Description of key information

One flash point experiment was conducted according to the closed cup method following the EU Method A.9 (Flash-Point) and ISO 2719:2002 (Determination of flash point - Pensky-Martens closed cup method) guideline and in compliance with GLP.  The flash point of Montaverdi has been determined as 94 degrees C @ 101900 Pa. Substance is not considered a flammable liquid because the flash point exceeds 60°C based on the classification criteria for flammable liquids (Annex I of CLP Section 2.6).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
94 °C