Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The study was conducted in compliance with GLP standards. The study was carried out according to Guideline A.17. However, full study report is not available as the data is > 12 year old and summaries have been prepared using data provided by ECHA.

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
1993

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
413-920-6
EC Name:
-
Cas Number:
88949-33-1
Molecular formula:
C30H20N2O2
IUPAC Name:
3,6-bis({[1,1'-biphenyl]-4-yl})-1H,2H,4H,5H-pyrrolo[3,4-c]pyrrole-1,4-dione
Constituent 2
Reference substance name:
3,6- bis-biphenyl-4-yl-2,5-dihydropyrrolo[3,4-c]pyrrole-1,4-dione
IUPAC Name:
3,6- bis-biphenyl-4-yl-2,5-dihydropyrrolo[3,4-c]pyrrole-1,4-dione

Results and discussion

Test results (Oxidising solids)open allclose all
Sample tested:
test mixture (not specified)
Remarks:
migrated information
Parameter:
maximum burning rate
Result:
ca. 2 other: mm/s (migrated information)
Sample tested:
reference mixture (not specified)
Remarks:
migrated information
Parameter:
maximum burning rate
Result:
ca. 3.8 other: mm/s (migrated information)

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
The study was conducted in accordance with GLP as per the Guideline A. 17. The test substance shows no oxdising properties.