Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The study was conducted in compliance with GLP standards. The study was carried out according to Guideline A.10. However, full study report is not available as the data is > 12 year old and summaries have been provided by ECHA.

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
1993

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
> 10 s
Remarks on result:
other: The test substance could be ignited with a flame but expired after 10 sec.
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

Extremely flammable (MethA9/A2) :N

Highly flammable:N

Pyrophoric substance(A13) :N

Highly flammable solid (A10) :N

Highly flammable liquid(A9) :N

Highly flammable gas(A11) :N

In contact with water substance liberate highly flammable gases (A12) :N

Flammable(A9) :N

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The study was conducted in accordance with GLP as per Guideline A. 10. The test substance was found to be non-flammable.