Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according to OECD/EU guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Remarks on result:
other: The test item had no flash point under atmospheric conditions (1013 hPa) up to a temperature of 230 °C, where it started boiling.

Applicant's summary and conclusion

Conclusions:
The test item had no flash point under atmospheric conditions (1013 hPa) up to a temperature of 230 °C, where it
started boiling.