Registration Dossier

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according OECD/EU guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method B.40 (In Vitro Skin Corrosion: Transcutaneous Electrical Resistance Test (TER))
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Test system

Vehicle:
unchanged (no vehicle)
Duration of treatment / exposure:
60 min

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
other:
Value:
69.33
Remarks on result:
other:
Remarks:
Time point: 3 min. (migrated information)
Irritation / corrosion parameter:
other:
Value:
1.18
Remarks on result:
other:
Remarks:
Time point: 60 min. (migrated information)

Applicant's summary and conclusion

Interpretation of results:
corrosive
Remarks:
Migrated information