Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according to OECD/EU guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
yes (incl. certificate)
Type of method:
dynamic method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
0 hPa
Temp.:
20 °C
Vapour pressure:
0.02 Pa
Temp.:
25 °C
Vapour pressure:
0.001 hPa
Temp.:
25 °C
Vapour pressure:
0.05 Pa
Temp.:
50 °C
Vapour pressure:
0.019 hPa
Temp.:
50 °C
Vapour pressure:
1.9 Pa

Applicant's summary and conclusion

Conclusions:
The vapour pressure values for the test item were extrapolated from the experimental data.