Registration Dossier

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
4 July 2003 to 11 July 2003
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
according to
Guideline:
other:
Version / remarks:
The determination of melting point was performed using a standard melting point apparatus.
Principles of method if other than guideline:
The determination of melting point was performed using a standard melting point apparatus (capillary)
GLP compliance:
yes (incl. certificate)
Type of method:
capillary method
Key result
Decomposition:
yes
Decomp. temp.:
168 - 169 °C
Conclusions:
Substance decomposes before reaching melting point. Onset point of decomposition was determined to be 168 to 169 degrees Celsius.

Description of key information

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
168 °C

Additional information