Registration Dossier

Diss Factsheets

Environmental fate & pathways

Endpoint summary

Administrative data

Description of key information

In a preliminary test performed according OECD 111, recoveries of the analogue substance solution was low for pH 4 (1.988% of initial), pH 7(11.401% of initial ) and pH 9 (11.401% of initial ). Due to the low recoveries it  can be asserted that  hydrolysis occurred within all of the pH environments and this was rapid (< 50% recovery at 2.4 hours in

all pH environments).

As >10% of the substance had been hydrolysed after 5 days, it is considered hydro-statically unstable under the conditions of this test.

Additional information

A hydrolysis test (OECD 111) with Fatty acids, C10-30, esters with lanolin alcs. is available, but no tests on Fatty acids, lanolin, esters with cholesterol-low lanolin alcs. are available. The outcome of the hydrolysis test for Fatty acids, C10-30, esters with lanolin alcs. will be used in a read-across for the structurally very similar Fatty acids, lanolin, esters with cholesterol-low lanolin alcs.