Registration Dossier

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report Date:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 105 (Water Solubility)
GLP compliance:
yes
Type of method:
column elution method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Purity: not reported

Results and discussion

Water solubility
Water solubility:
< 3 other: ppm
Temp.:
20 °C
pH:
>= 0 - <= 14
Details on results:
No test substance was found in any of the water solubility samples. The method limit of detection was calculated using linear regression from the calibration standards. The water solubility is reported as less than this calculated limit of detection, <3 ppm.

Applicant's summary and conclusion

Conclusions:
Less than the limit of detection, <3 ppm.
Executive summary:

The water solubility of the test substance was determined using the column elution method described in OECD 105. No test substance was found in any of the water solubility samples. The method limit of detection was calculated using linear regression from the calibration standards. The water solubility is reported as less than this calculated limit of detection, <3 ppm.