Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report Date:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
GLP compliance:
yes
Type of method:
capillary method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Purity: not reported

Results and discussion

Melting / freezing point
Decomposition:
yes
Remarks:
Decomposed before melting
Decomp. temp.:
135 °C

Applicant's summary and conclusion

Conclusions:
Decomposed at 135ºC
Executive summary:

Decomposed at 135ºC