Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions) - Method B: Fibre Length and Diameter Distributions
Deviations:
no
GLP compliance:
yes
Type of method:
sieving
Remarks:
Scanning electron microscopy
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
Batch number: CN61204501
Date of receipt: 2017-03-02
Expiry date: 2018-07-24
Mass median aerodynamic diameter:
5.41 µm
Size:
< 4 µm
Distribution:
3.04 %
Remarks on result:
other: Spherical Volume
Size:
< 4 µm
Distribution:
3.23 %
Remarks on result:
other: Cubical Volume
Size:
>= 4 - <= 10 µm
Distribution:
41.72 %
Remarks on result:
other: Spherical Volume
Size:
>= 4 - <= 10 µm
Distribution:
42.72 %
Remarks on result:
other: Cubical Volume
Size:
>= 10 - <= 100 µm
Distribution:
55.24 %
Remarks on result:
other: Spherical Volume
Size:
>= 10 - <= 100 µm
Distribution:
54.05 %
Remarks on result:
other: Cubical Volume
Size:
> 100 µm
Distribution:
0 %
Remarks on result:
other: Spherical Volume
Size:
> 100 µm
Distribution:
0 %
Remarks on result:
other: Cubical Volume

Conclusion

       Accounting based on the total sample weight
   Particle Size [μm]  Spherical Volume [%]
 Mass Fraction  >100  26.93
 Sieve Fraction  >100  0.00
 Total (>100μm)    26.93
 Sieve Fraction  10 -100 (inhalable)  40.37
 Sieve Fraction  4-10 (thoracic)  30.49
 Sieve Fraction  <4 (respirable)  2.22

The MMAD (Mass Median Aerodynamic Diameter < 100 µm) has a value of 5.41 µm as spherical particles.

Conclusions:
The particle size distribution of Vulkacit P extra N was determined by scanning electron microscopy after the samples was fractionated by a 100 μm sieve. The MMAD (Mass Median Aerodynamic Diameter < 100 µm) has a value of 5.41 µm as spherical particles.
Executive summary:

The particle size distribution of Vulkacit P extra N was determined by scanning electron microscopy after the samples was fractionated by a 100 μm sieve.

Sieve Fraction:

weighted sample: 0.8059 g

weight fraction <100 μm: 0.5889 g

mass fraction <100 μm: 73.07 %

Mass Fraction:

Sieve Fraction nominal < 100μm

 Particle Size  Spherical Volume  Cubical Volume
 <4 μm (respirable)  3.04 %  3.23 %
 4-10 μm (thoracic)  41.72 %  42.72 %
 10-100 μm (inhalable)  55.24 %  54.05 %
 >100 μm  0.00 %   0.00 %
 Median (diameter μm)  5.41 μm  5.22 μm

The MMAD (Mass Median Aerodynamic Diameter < 100 µm) has a value of 5.41 µm as spherical particles.

       Accounting based on the total sample weight

   Particle Size [μm]  Spherical Volume [%]
 Mass Fraction  >100  26.93
 Sieve Fraction  >100  0.00
 Total (>100μm)    26.93
 Sieve Fraction  10-100 (inhalable)  40.37
 Sieve Fraction  4-10 (thoracic)  30.49
 Sieve Fraction  <4 (respirable)  2.22

Description of key information

The particle size distribution of Vulkacit P extra N was determined by scanning electron microscopy after the samples was fractionated by a 100 μm sieve.

Sieve Fraction:

weighted sample: 0.8059 g

weight fraction <100 μm: 0.5889 g

mass fraction <100 μm: 73.07 %

Mass Fraction:

Sieve Fraction nominal < 100μm

 Particle Size  Spherical Volume  Cubical Volume
 <4 μm (respirable)  3.04 %  3.23 %
 4-10 μm (thoracic)  41.72 %  42.72 %
 10-100 μm (inhalable)  55.24 %  54.05 %
 >100 μm  0.00 %   0.00 %
 Median (diameter μm)  5.41 μm  5.22 μm

The MMAD (Mass Median Aerodynamic Diameter < 100 µm) has a value of 5.41 µm as spherical particles.

       Accounting based on the total sample weight

   Particle Size [μm]  Spherical Volume [%]
 Mass Fraction  >100  26.93
 Sieve Fraction  >100  0.00
 Total (>100μm)    26.93
 Sieve Fraction  10-100 (inhalable)  40.37
 Sieve Fraction  4-10 (thoracic)  30.49
 Sieve Fraction  <4 (respirable)  2.22

Additional information