Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Remarks:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28 Feb 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
31 May 2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D 6450
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
other: see Remarks
Remarks:
continuously closed cup - electric arc method
Flash point apparatus:
Pensky-Martens apparatus
Remarks:
MINIFLASH FLP, Grabner Instruments, Austria
Remarks on result:
no flash point according to standard method

The test item was measured with two parallel tests. The parameters used for the flash point determinations are presented in table above. The measured flash point of C6OLF was: no flash point was observed up to 200 °C.

Description of key information

Not applicable.

Key value for chemical safety assessment

Additional information

The test substance has no flash point up to 200 °C (Continuously closed-up electric arc, ASTM D 6450).