Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 241-602-5 | CAS number: 17625-03-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Genetic toxicity: in vitro
Administrative data
- Endpoint:
- in vitro gene mutation study in bacteria
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 017
- Report date:
- 2017
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 471 (Bacterial Reverse Mutation Assay)
- Version / remarks:
- Adopted July 1997
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.13/14 (Mutagenicity - Reverse Mutation Test Using Bacteria)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of assay:
- bacterial reverse mutation assay
Test material
- Reference substance name:
- Sodium hydrogen m-sulphonatobenzoate
- EC Number:
- 241-602-5
- EC Name:
- Sodium hydrogen m-sulphonatobenzoate
- Cas Number:
- 17625-03-5
- Molecular formula:
- C7H6O5S.Na
- IUPAC Name:
- sodium 3-sulfobenzoate
- Test material form:
- solid: particulate/powder
- Details on test material:
- White crystalline powder.
Constituent 1
- Specific details on test material used for the study:
- Identity Sodium 3-sulfobenzoate
Alternative names 3-Sulpho Benzoic Acid Mono Sodium Salt
SBA (3-Sodiosulfobenzoic Acid)
Sodium hydrogen m-sulphonatobenzoate
Label name 3-Sodiosulfobenzoic Acid
Batch no. 170103
Expiry date 14 February 2019
Storage conditions Room temperature
RTC number 15432
Method
Species / strainopen allclose all
- Species / strain / cell type:
- S. typhimurium TA 1535, TA 1537, TA 98 and TA 100
- Additional strain / cell type characteristics:
- other: deficient in a DNA excision repair system (uvrB mutation)
- Species / strain / cell type:
- E. coli WP2 uvr A
- Additional strain / cell type characteristics:
- other: uvrA DNA repair deficiency
- Metabolic activation:
- with and without
- Metabolic activation system:
- S9 tissue homogenate
- Test concentrations with justification for top dose:
- A preliminary toxicity test was undertaken in order to select the concentrations of the test item to be used in the Main Assays. In this test a wide range of dose levels of the test item, set at half-log intervals, was used. Treatments were performed both in the absence and presence of S9 metabolism using the plate incorporation method; a single plate was used at each test point and positive controls were not included. Toxicity was assessed on the basis of a decline in the number of spontaneous revertants, a thinning of the background lawn or a microcolony formation.
Solubility of the test item was evaluated in a preliminary trial using DMSO. This solvent was selected since it is compatible with the survival of the bacteria and the S9 metabolic activity. A clear solution without any visible precipitation was obtained at 100mg/mL following few minutes of vortexing. This result permitted a maximum concentration of 5000 μg/plate to be used in the toxicity test.
Toxicity test
The test item Sodium 3-sulfobenzoate was assayed in the toxicity test at a maximum dose level of 5000 μg/plate and at four lower concentrations spaced at approximately half-log intervals: 1580, 500, 158 and 50.0 μg/plate.
No precipitation of the test item was observed at the end of the incubation period at any concentration. Neither toxic effects, nor relevant increases in revertant numbers were observed with any tester strain, at any dose level, in the absence or presence of S9 metabolic activation.
Main Assay
Two Main Assays were performed. Individual plate counts for these tests and the mean and standard error of the mean for each test point. On the basis of the results obtained in the preliminary toxicity test, in Main Assay I, using the plate incorporation method, the test item was assayed at the maximum dose level of 5000 μg/plate (the upper limit to testing indicated in the Study Protocol) and at four lower dose levels spaced by a factor of two: 2500, 1250, 625 and 313 μg/plate. - Vehicle / solvent:
- Solubility of the test item was evaluated in a preliminary trial using DMSO. This solvent was selected since it is compatible with the survival of the bacteria and the S9 metabolic activity. A clear solution without any visible precipitation was obtained at 100mg/mL following few minutes of vortexing. This result permitted a maximum concentration of 5000 μg/plate to be used in the toxicity test.
Controls
- Untreated negative controls:
- yes
- Negative solvent / vehicle controls:
- no
- True negative controls:
- no
- Positive controls:
- yes
- Positive control substance:
- 9-aminoacridine
- 2-nitrofluorene
- sodium azide
- methylmethanesulfonate
- other: 2-aminoanthracene
- Details on test system and experimental conditions:
- Tester strain Absence of S9 Presence of S9
TA1535 sodium azide 2-aminoanthracene
TA100 sodium azide 2-aminoanthracene
TA1537 9-amino-acridine 2-aminoanthracene
TA98 2-nitrofluorene 2-aminoanthracene
WP2 uvrA methylmethanesulphonate 2-aminoanthracene
Four strains of Salmonella typhimurium (TA1535, TA1537, TA98 and TA100) and a strain of Escherichia coli (WP2 uvrA) were used in this study.
TA1535 and TA100 are predominantly sensitive to base pair mutagens, TA1537 and TA98 are sensitive to frameshift mutagens. In addition to a mutation in the histidine operon, the Salmonella tester strains contain additional mutations which enhance their sensitivity to some mutagenic compounds. The rfa wall mutation results in the loss of one of the enzymes responsible for the synthesis of part of the lipopolysaccharide barrier that forms the surface
of the bacterial cell wall and increases permeability to certain classes of chemicals. All strains are deficient in a DNA excision repair system (uvrB mutation) which enhances the sensitivity to some mutagens. TA98 and TA100 strains contain the pKM101 plasmid which activates an error prone DNA repair system. Tester strain WP2 uvrA is reverted from tryptophan dependence (auxotrophy) to tryptophan independence (prototrophy) by base substitution mutagens. In addition to the mutation in the tryptophan operon, the tester strain contains an uvrA DNA repair deficiency which enhances its sensitivity to some mutagenic compounds.
Permanent stocks of these strains are kept at -80°C in RTC. Overnight subcultures of these stocks were prepared for each day’s work. Bacteria were taken from vials of frozen cultures, which had been checked for the presence of the appropriate genetic markers, as follows:
Histidine requirement No Growth on Minimal plates+Biotin.
Growth on Minimal plates+Biotin+Histidine.
Tryptophan requirement No Growth on Minimal agar plates.
Growth on Minimal plates+Tryptophan.
uvrA, uvrB Sensitivity to UV irradiation.
rfa Sensitivity to Crystal Violet.
pKM101 Resistance to Ampicillin.
Bacterial cultures in liquid and on agar were clearly identified with their identity.
Media
The following growth media were used:
Nutrient Broth
Oxoid Nutrient Broth No. 2 was prepared at a concentration of 2.5% in distilled water and autoclaved prior to use. This was used for the preparation of liquid cultures of the tester strains.
Nutrient Agar
Oxoid Nutrient Broth No. 2 (25 g) and Difco Bacto-agar (15 g) were added to distilled water (1 litre) and autoclaved. The solutions were then poured into 9 cm plastic Petri dishes and allowed to solidify and dry before use. These plates were used for the non-selective growth of the tester strains.
Minimal Agar
Minimal medium agar was prepared as 1.5% Difco Bacto-agar in Vogel-BonnerMedium E, with 2% Glucose, autoclaved and poured into 9 cm plastic Petri dishes.
Top Agar
"Top Agar" (overlay agar) was prepared as 0.6% Difco Bacto-agar + 0.5% NaCl in distilled water and autoclaved. Prior to use, 10mL of a sterile solution of 0.5 mM Biotin + 0.5 mM Histidine (or 0.5mMtryptophan) was added to the top agar (100 mL).
S9 tissue homogenate
One batch of S9 tissue fraction, provided by Trinova Biochem GmbH, was used in this study and had the following characteristics:
Species Rat
Strain Sprague Dawley
Tissue Liver
Inducing Agents Phenobarbital – 5,6-Benzoflavone
Producer MOLTOX,Molecular Toxicology, Inc.
Batch Number 3770
The mixture of S9 tissue fraction and cofactors (S9 mix) was prepared as follows (for each 10 mL):
S9 tissue fraction 1.0 mL
NADP (100 mM) 0.4 mL
G-6-P (100 mM) 0.5 mL
KCl (330 mM) 1.0 mL
MgCl2 (100 mM) 0.8 mL
Phosphate buffer (pH 7.4, 200 mM) 5.0 mL
Distilled Water 1.3mL - Rationale for test conditions:
- A preliminary toxicity test was undertaken in order to select the concentrations of the test item to be used in the Main Assays. In this test a wide range of dose levels of the test item, set at half-log intervals, was used. Treatments were performed both in the absence and presence of S9 metabolism using the plate incorporation method; a single plate was used at each test point and positive controls were not included. Toxicity was assessed on the basis of a decline in the number of spontaneous revertants, a thinning of the background lawn or a microcolony formation.
- Evaluation criteria:
- The prepared plates were inverted and incubated for approximately 72 hours at 37°C. After this period of incubation, plates from the preliminary toxicity test were held at 4°C for approximately 24 hours before scoring, while plates from Main Assays were immediately scored by counting the number of revertant colonies on each plate.
- Statistics:
- Regression lines are calculated using a minimum of the three lowest dose levels, and then including the further dose levels in turn. The correlation co-efficient (r), the value of students "t" statistic, and the p-value for the regression lines are also given.
Results and discussion
Test resultsopen allclose all
- Species / strain:
- S. typhimurium TA 1535
- Metabolic activation:
- with and without
- Genotoxicity:
- negative
- Cytotoxicity / choice of top concentrations:
- no cytotoxicity
- Vehicle controls validity:
- valid
- Untreated negative controls validity:
- valid
- Positive controls validity:
- valid
- Species / strain:
- S. typhimurium TA 1537
- Metabolic activation:
- with and without
- Genotoxicity:
- negative
- Cytotoxicity / choice of top concentrations:
- no cytotoxicity
- Vehicle controls validity:
- valid
- Untreated negative controls validity:
- valid
- Positive controls validity:
- valid
- Species / strain:
- S. typhimurium TA 98
- Metabolic activation:
- with and without
- Genotoxicity:
- negative
- Cytotoxicity / choice of top concentrations:
- no cytotoxicity
- Vehicle controls validity:
- valid
- Untreated negative controls validity:
- valid
- Positive controls validity:
- valid
- Species / strain:
- S. typhimurium TA 100
- Metabolic activation:
- with and without
- Genotoxicity:
- negative
- Cytotoxicity / choice of top concentrations:
- no cytotoxicity
- Vehicle controls validity:
- valid
- Untreated negative controls validity:
- valid
- Positive controls validity:
- valid
- Species / strain:
- E. coli WP2 uvr A
- Metabolic activation:
- with and without
- Genotoxicity:
- negative
- Cytotoxicity / choice of top concentrations:
- no cytotoxicity
- Vehicle controls validity:
- valid
- Untreated negative controls validity:
- valid
- Positive controls validity:
- valid
- Additional information on results:
- Solubility
Solubility of the test item was evaluated in a preliminary trial using DMSO. This solvent was selected since it is compatible with the survival of the bacteria and the S9 metabolic activity. A clear solution without any visible precipitation was obtained at 100mg/mL following few minutes of vortexing. This result permitted a maximum concentration of 5000 μg/plate to be used in the toxicity test.
Toxicity test
The test item Sodium 3-sulfobenzoate was assayed in the toxicity test at a maximum dose level of 5000 μg/plate and at four lower concentrations spaced at approximately half-log intervals: 1580, 500, 158 and 50.0 μg/plate.
No precipitation of the test item was observed at the end of the incubation period at any concentration.
Neither toxic effects, nor relevant increases in revertant numbers were observed with any tester strain, at any dose level, in the absence or presence of S9 metabolic activation.
Main Assay
Two Main Assays were performed. On the basis of the results obtained in the preliminary toxicity test, in Main Assay I, using the plate incorporation method, the test item was assayed at the maximum dose level of 5000 μg/plate (the upper limit to testing indicated in the Study Protocol) and at four lower dose levels spaced by a factor of two: 2500, 1250, 625 and 313 μg/plate. No toxicity was observed at any concentration with any tester strain/activation condition combinations.
As no relevant increase in revertant numbers was observed at any concentration tested, a Main Assay II was performed including a pre-incubation step for all treatments and using the same dose levels ofMain assay I.
Neither toxic effects, nor increases in the revertant colonies were noted with any tester strain, at any concentration tested, in the absence or presence of S9 metabolism.
The sterility of the S9 mix and of the test item solutions was confirmed by the absence of colonies on additional agar plates spread separately with these solutions. Marked increases in revertant numbers were obtained in these tests following treatment with the positive control items, indicating that the assay system was functioning correctly.
No precipitation of the test item was observed at the end of the incubation period in the absence or presence of S9 metabolic activation, in any experiment.
Acceptance criteria
The assay was considered valid if the following criteria were met:
1. Mean plate counts for untreated and positive control plates should fall within 2 standard deviations of the current historical mean values.
2. The estimated numbers of viable bacteria/plate should fall in the range of 100 – 500 millions for each strain.
3. No more than 5% of the plates should be lost through contamination or other unforeseen event.
Criteria for outcome of the assays
For the test item to be considered mutagenic, two-fold (or more) increases in mean revertant numbers must be observed at two consecutive dose levels or at the highest practicable dose level only. In addition, there must be evidence of a dose-response relationship showing increasing numbers of mutant colonies with increasing dose levels.
Evaluation
Results show that mean plate counts for untreated and positive control plates fell within the normal range based on historical control data. The estimated numbers of viable bacteria/plate (titre) fell in the range of 100 - 500 million for each tester strain. No plates were lost through contamination or cracking. The study was
accepted as valid.
The test item did not induce two-fold increases in the number of revertant colonies, at any dose level, in any tester strain, in the absence or presence of S9 metabolism.
Applicant's summary and conclusion
- Conclusions:
- It is concluded that the test item Sodium 3-sulfobenzoate does not induce reverse mutation in Salmonella typhimurium or Escherichia coli in the absence or presence of S9 metabolism, under the reported experimental conditions.
- Executive summary:
The test item Sodium 3-sulfobenzoate was examined for the ability to induce gene mutations in tester strains of Salmonella typhimurium and Escherichia coli, as measured by reversion of auxotrophic strains to prototrophy. The five tester strains TA1535, TA1537, TA98, TA100 and WP2 uvrA were used. Experiments were performed both in the absence and presence of metabolic activation, using liver S9 fraction from rats pre-treated with phenobarbital and 5,6-benzoflavone.
The test item was used as a solution in dimethylsulfoxide (DMSO).
It is concluded that the test item Sodium 3-sulfobenzoate does not induce reverse mutation in Salmonella typhimurium or Escherichia coli in the absence or presence of S9 metabolism, under the reported experimental conditions.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.