Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014-11-21 to 2014-11-21
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO No., other: DIN EN ISO 13736
Version / remarks:
2013
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Abel apparatus
Key result
Flash point:
44.5 °C
Atm. press.:
1 011.6 hPa

Preliminary Test results

Amount of test item / g

Temperature / °C

Ignition (+/-)*

Air pressure / hPa

66.883

45.0

+

1011.6

*) + (“Ignition”); - (“no ignition”)

The lowest temperature where an ignition was observed was 45.0 °C.

Main Test results:

The lowest temperature where an ignition was observed was 44.0 °C. The measured flash point is corrected to the ambient pressure to be 44.535 °C. The resulting average corrected flash point rounded down to the nearest multiple of 0.5 °C is 44.5 °C.

Main test:

amount of test item / g

temperature / °C

ignition (+/-)

air pressure / hPa

flash point (corr.) / °C

67.68

44.0

+

1011.6

44.035

65.71

45.0

+

1011.6

45.035

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The test item has a flash point of 44.5 °C (average corrected and rounded down to the nearest multiple of 0.5 °C).
According to the results of the test on the flash point, the test item is classified as following:

GHS (CLP Regulation EC 1272/2008 Annex 1: 2.6): With a measured flash point between >=21 °C and <= 55 °C, the test item has to be classified as flammable liquid of Category 3 and marked with the warning ‘H226: flammable liquid and vapour ’ according to GHS or CLP Regulation EC 1272/2008 Annex 1.
UN Transport Regulation: With a measured flash point between >=21 °C and <= 55 °C, the test item has to be classified as flammable liquid in class 3 of packaging group III.


Executive summary:

The test item has a flash point of 44.5 °C (average corrected and rounded down to the nearest multiple of 0.5 °C) according to Regulation EC No. 440/2008 Method A.9.Flash Point, and DIN EN ISO 13736 (2013) Abel Closed cup test.

Description of key information

Flash point: 44.5°C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
44.5 °C

Additional information

The test item has a flash point of 44.5 °C (average corrected and rounded down to the nearest multiple of 0.5 °C) according to Regulation EC No. 440/2008 Method A.9.Flash Point, and DIN EN ISO 13736 (2013) Abel Closed cup test.