Registration Dossier

Physical & Chemical properties

Additional physico-chemical information

Administrative data

Endpoint:
additional physico-chemical information
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: According to guideline, but not GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report Date:
2008

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: VDI 2263, Part 1 (May 1990) Dust Fires and Dust Explosions, Hazards – Assessment - Protective Measures, Test Methods for the Determination of Safety Characteristic of Dusts.
GLP compliance:
no
Endpoint investigated:
minimum ignition energy

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Di-TMP micronized, Perstorp ID 0805-PTP-DITMP-3686200. Median particle size= 33.4 µm.

Results and discussion

Results:
The Minimum Ignition Energy (M.I.E) without inductivity was determined for the sample “Di-TMP micronized; Perstorp ID 0805-PTP-DITMP-3686200” with 1 mJ

Applicant's summary and conclusion

Conclusions:
The Minimum Ignition Energy (M.I.E) without inductivity was determined for the sample “Di-TMP micronized; Perstorp ID 0805-PTP-DITMP-3686200” with 1 mJTherewith, the dust is specified according to the literature (2) as “extremely ignitable”.

(2) Klais, O.; H. Franke; M. Glor; B. Maurer und C.-D. Walther: Vermeiden von Zundquellen als vorbeugender Explosionsschutz,
VDI-Berichte Nr. 975, S. 543-560, VDI-Verlag, Dusseldorf 1992.
Assessment criteria:
M.I.E. >=10 mJ: normally ignitable
3<=M.I.E.< 10 mJ: especially ignitable
M.I.E. < 3 mJ: extremely ignitable
Executive summary:

The Minimum Ignition Energy (M.I.E) without inductivity was determined for the sample “Di-TMP micronized; Perstorp ID 0805-PTP-DITMP-3686200” with 1 mJ<M.I.E.<3 mJ.

Therewith, the dust is specified according to the literature (2) as “extremely ignitable”.

(2) Klais, O.; H. Franke; M. Glor; B. Maurer und C.-D. Walther: Vermeiden von Zundquellen als vorbeugender Explosionsschutz,

VDI-Berichte Nr. 975, S. 543-560, VDI-Verlag, Dusseldorf 1992.

Assessment criteria:

M.I.E. >=10 mJ: normally ignitable

3<=M.I.E.< 10 mJ: especially ignitable

M.I.E. < 3 mJ: extremely ignitable